Post process settings – Spectra Precision Survey Pro v4.6 Recon-Nomad Reference Manual User Manual
Page 122
Survey Pro Reference Manual
R-114
Post Process Settings
Job Settings Post Process
.
or
Connect to Receiver Receiver Settings
.
The Post Process card is used to configure the settings for logging
post processing data, and the collecting and storing of post processing
points in Survey Pro.
RTK Autonomous Points:
is where you specify action to
take when accepting autonomous points during RTK
data collection. There are three options.
• Do not store: this option will prohibit acceptance
of autonomous points in RTK data collection
routines.
• Prompt for layer: this option will prompt the
user whenever an autonomous point is accepted.
The layer specified will be the default layer to
store autonomous points, but the user can over
ride at the prompt.
• Store on selected layer: this option will
automatically store autonomous points accepted
during RTK data collection routines on the
specified layer.
Layer
: displays the layer selected to store autonomous points.
Select Layer : opens up a layer prompt to allow you to select an
existing layer or create a new layer to store autonomous points.
Session Monitor
: is where you select to use the session monitoring
thresholds when collecting data with the Static / Rover Session
screen. To have Survey Pro display warnings during post processing
data collection, check Warn me if, and specify threshold values for the
number of SV, HDOP and memory.