Miscellaneous Screens

R-459

Edit Smart Target

, Manage Smart Targets, Add or Edit

.

The Edit Smart Target screen is used to edit an existing Smart

Target or create a new one.

Name: is the desired name for the Smart Target.
Target Type: defines the type of target as being a Prism,
Reflectorless, Long Range, which increases the EDM
power, or On Gun, which uses whichever EDM settings

are configured on the total station (for Leica total
stations only).
HR: is the default HR for the Smart Target.
Add Offset to HR: When checked, the offset entered will
always automatically be added to the HR entered for the

Smart Target.
Prism Constant: is the prism constant for the Smart
Target.

Note: If a prism constant is entered for a Smart Target

while a prism constant is also set in the total station, the prism

constant will be applied twice, resulting in incorrect distance
measurements for every shot. Be sure the prism constant is set to

zero in the total station if entering a value for a Smart Target, or
vice-versa.

Prism Type: This option allows you to choose one of the following

three types of prisms when using a supported Trimble total station:

• Generic: Select this option if using a generic (non-Trimble

360°) prism. It is up to the user to enter the correct prism
constant and manually angle the prism vertically toward the

total station before taking any shots to avoid introducing

error.

• Trimble 360° (2mm): Select this option when using a Trimble

360° prism. This selection will apply the appropriate vertical
angle correction constant for this prism to correct the error