R-198
Feature : opens the Feature Collection screen, where various
automatic and manual data collection options are available.
Offset : opens the Offset Shots screen, where a point can be collected
and stored at a specified offset.
Point : opens the Occupy Data Points screen (Page R-201), used to
occupy and store a new point.
Feature Collection Screen
Survey Data Collection
Feature
.
The Feature Collection screen is used when you wish to set up
automated continuous data collection.
Points to be Stored
: displays the starting point name
and description of the group of points to be stored.
Method
: is where you select the method of continuous
data collection. The available methods are described
below:
• Time Interval: After accepting the first point,
additional points will automatically be stored
after the specified time interval (in seconds) has
elapsed. Each successive point name is
incremented to the next available name.
• Distance Interval 2D / 3D: After accepting the
first point, additional points will automatically
be stored after traveling the specified horizontal
or 3D distance. Each successive point name is
incremented to the next available name.
• Hold Still For: After accepting the first point, additional
points are automatically stored when the pole is held in the
same spot for the specified interval of time (in seconds).
• Manual: prompt once: stores points in the same way as
tapping Topo SS from the Data Collection screen,
incrementing the point name after each stored point.
• Manual: prompt every point: performs the same function as
the Manual Prompt Once routine, above, except you are