beautypg.com

Curve and offset – screen three – Spectra Precision Survey Pro v4.6 Recon-Nomad Reference Manual User Manual

Page 322

background image

Survey Pro Reference Manual

R-314

Curve and Offset – Screen Three

Station: displays the current station that is being

staked.
H. Offset: displays the offset distance of the curve being
staked from the specified curve and if it is on the Right
or Left side of the specified curve.
Angle Right: is the horizontal angle that the total

station must aim toward so that it is facing the current
station.
Horz. distance: is the horizontal distance from the
occupy point to the current station.
Vert Distance: is the vertical distance from the occupy
point to the current station.
ZE to Rod: is the zenith angle that the total station must
aim toward so that it is facing the current station.

Circle Zero : is used to modify the circle on the total station so that

the angle right reading will be zero when it is facing toward the

design point, which can sometimes be easier than turning to an
obscure angle value. When this button is tapped, the following

actions will occur:
1. A new backsight circle value is computed, sent to the instrument

and stored in the raw data.

2. The Angle Right value is changed to zero to reflect the change. The

instrument now needs to be turned horizontally to zero to face the

design point.

3. To prevent errors, the backsight set up is invalidated when

exiting the Stakeout dialog if this button has been used. A circle

zeroed on a design point is meaningless once the design point has
been staked.

Note: The Circle Zero button is not available when using a robotic
total station.

< Back : returns to the previous screen.