Survey Pro Reference Manual

R-126

Set Backsight Circle: Once the circle value of the

instrument has been set or read, the symbol will be
replaced with a .

Store Backsight Point : This button is only available

when the backsight is defined by a direction instead of a
point and is used if you want to take a shot and store a

point for the current backsight. Once stored, the button
will be replaced by the new point name.
BS Circle: This is the horizontal angle to set in the
instrument. This will usually be zero, but when Survey

with True Azimuths is enabled in the Surveying Settings
screen (Page R-45), this will be the computed azimuth to

the current backsight.

Remote… : When connected to a robotic total station,

this opens the Remote Control screen (Page R-168) to remotely aim
the total station. This is particularly useful when using a fixed

backsight with a Smart Target because the Remote Control screen

will then automatically reflect the prism configuration at the
backsight.

Send Circle : This will send the circle entered in the BS Circle field to

the instrument.

Read Circle : Will read the current horizontal angle from the

instrument and set that as the backsight circle. (Non-zero backsight
circle values are typically used only when surveying in true

azimuths.)
Check Backsight: Once the backsight has been checked by distance

or angle, the symbol will be replaced with a .

By Distance : will take a shot to a prism located over the backsight

point and compare the measured distance with the computed distance

between the occupy and backsight points stored in the current job.

Note: Checking the backsight by shooting a distance does not apply if
the backsight is defined by a direction.