305
Scenario Examples
Teledyne LeCroy
Scenario Examples
A few examples are described, one in Simple Mode and one in the Advanced Mode.
Example 1 in Simple Mode
In this example, the Arm Event is an Extended Link Service Request with ELS Command:
RRQ (0x12) (From Originator), the Arm Rollback In is set after a specific duration of 10
seconds. In Jam Details the Jam Event is set for an ARB Loop Initialization and the Jam
Action is to insert a frame and beep.
Perform the following steps to create this Scenario:
1. Select New Scenario from the File menu or click the New Scenario icon in the
toolbar of the main window or the File Library.
Settings
2. Enter the Scenario Name in the field provided in Settings. In this example the
Scenario Name is Simple Example 1.
3. Select the Jam Direction from the drop‐down menu to choose the direction of traffic
to monitor the selected Event (the default is From P1/P3), which is selected for this
example).
4. Select Repeat Jam value from the drop‐down menu. In this case once is selected.
Arm Detail
5. Select the Arm Exists checkbox to add an Arm Event.
6. In this example the Arm Event is an Extended Link Service Request with ELS
Command: RRQ (0x12) (From P1/P3). You can select the Arm Rollback In from the
drop‐down list. In this case the Arm Rollback In is After Specific Duration of 10
seconds.
Jam Details
7. Specify the Jam Event to be performed. In this example the Jam Event is an ARB Loop
Initialization; Loop Init ID: Any [0x11XXXXX] [From P1/P3].
Jam Action
8. The Jam Action specified is to Insert Frame [SOF : SOFc1 CRC : Auto Calculate CRC
|EOF : EOFt]; followed by a Beep for a duration of 50 ms.