beautypg.com

Timers/external – Teledyne LeCroy SierraFC M164 User Manual User Manual

Page 157

background image

    

SierraFC M164 Protocol Analyzer User Manual

157

Easy Mode (Pre‐Defined Setups)

 Teledyne LeCroy

VSAN‐ADVB

ADVB(Object0)

ADVB(Object2/3)

Custom Frame

Protocol Errors

Choosing a Parameter
Either highlight the category and click the 

+>>

 button, or double‐click the category, to 

open a corresponding definition dialog. Click on the Okay button to move the pattern to 
the Active pane.

To remove an item, highlight it in the Project Tree, then click the 

‐<<

 button.

Timers/External

Selecting a timer for a trigger in the Any Trigger Mode limits the time that the analyzer 
looks for selected triggering conditions before triggering. The timer activates when the 
Project runs. If none of the selected triggering conditions occurs during the timer’s active 
time, the Analyzer triggers at the end of the time set for the timer.

Timer

You can set a timer independently of any other trigger selection, to cause an 
unconditional trigger after a set time.

Double‐click Timer in the Pattern window to open the Add Timer Pattern dialog.

Figure 2.120: Add Timer Pattern Dialog

Check a Time Unit, enter the Timer Value, and click OK.

Note:

The timer and timeout resolution is limited to one DWORD. The minimum value is 12‐13 

DWORD.