Advanced Mode (User‐Defined)
178
SierraFC M164 Protocol Analyzer User Manual
Setting Trigger Conditions
To set the If and Else If trigger condition:
1. Click the Add Pattern button
for a Pattern field and choose a trigger
condition from the drop‐down list.
Figure 2.134: Choosing a Trigger Condition
2. Define each selected pattern in the same way as in Easy Mode, as described starting
. To use a timer, define it first.
Note:
You can set a timer for any If or Else If condition.
3. Enter a value for the number of occurrences before trigger in the Cont field, up to a
maximum of 65535 occurrences.
4. Choose a capture option: Everything, Nothing, or Pattern.
5. If you choose Everything, you can select primitives for exclusion. See
If you choose Pattern, you can select patterns for inclusion or exclusion. See
“Defining Patterns” on page 47
6. Choose pattern(s) and click the +>> button to add them for capture or exclusion. You
define each pattern the same way as in Easy mode (
“Defining Patterns” on page 47
).
7. For an output trigger, click the down arrow in the Ext. Out field and choose an
output trigger level. Note: Do not use the LOW setting in Advanced Mode.