External Trig Setting

The External Trig Setting dialog displays the External Trig Out Setting and External Trig In 
Setting as High Active, Low Active, or Toggle.

Figure 3.79: External Trigger Setting Dialog

To display the External Trig Setting dialog, select Configuration > External Trig Setting.

External Trig Out Setting
The Analyzer can send a Low or High external signal anytime a trigger occurs. Select the 
External Trig Out Setting: High Active, Low Active, or Toggle from High to Low or Low to 
High once (3.3 V output).

Enter the External TrigOut pulse width.

External Trig In Setting
An external Low or High input signal can cause triggering. Select the 
External Trig In Setting: High Active, Low Active, or Toggle from High to Low or Low to 
High once (3.3 V output).

Note:

The nominal External Trigger voltage is 0.818 volts. Trigger In can work with 1 volt to 5 volts 

input voltage.