B&B Electronics EIRM-EXTEND-8 - Manual User Manual
Page 177

Manual Documentation Number: EIRM-EXTEND-8-1411m
171
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
switch_a(config)#clock timezone YST9YDT
switch_a(config)#
Polling Interval:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen.
switch_a(config)#
2. Usage:
Use this command to specify the polling interval.
3. Command Syntax:
ntp polling-interval MINUTE
MINUTE <1-10080> The polling interval. Enter a value in the range 1 to
10080 minutes.
4. Example:
The following example specifies the polling interval 60 minutes:
switch_a(config)#ntp polling interval 60
switch_a(config)#
Daylight Saving Mode:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen.
switch_a(config)#
2. Usage:
Use this command to enable daylight saving.
Use no clock summer-time command to disable daylight saving.
3. Command Syntax:
clock summer-time TIMEZONE weekday WEEK DAY MONTH HOUR
MINUTE WEEK DAY MONTH HOUR MINUTE OFFSET
TIMEZONE Specifies the daylight saving timezone.
WEEK <1-5> Specifies weekdays from Monday to Friday.
DAY <0-6> Specifies from Sunday to Saturday.
MONTH <1-12> Specifies from January to December.
HOUR <0-23> Specifies from 0 to 23.
MINUTE <0-59> Specifies from 0 to 59.