beautypg.com

B&B Electronics EIRM-EXTEND-8 - Manual User Manual

Page 159

background image

Manual Documentation Number: EIRM-EXTEND-8-1411m

153

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com

B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com

3. Command Syntax:
radius-server timeout SEC
no radius-server timeout
SEC <1-1000> The number of seconds for a Ethernet Extender Switch to
wait for a server host to reply before timing out. Enter a value in the range
1 to 1000.

4. Example:
The following example specifies 20 seconds for the Ethernet Extender
Switch to wait for a server host to reply before timing out:

switch_a(config)#radius-server timeout 20
switch_a(config)#


Retransmit:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen.

switch_a(config)#


2. Usage:
Use this command to specify the number of times the Ethernet Extender
Switch transmits each radius request to the server before giving up.

3. Command Syntax:
radius-server retransmit RETRIES
no radius-server retransmit
RETRIES <1-100> Specifies the retransmit value. Enter a value in the
range 1 to 100.

4. Example:
The following example specifies the retransmit value 12:

switch_a(config)#radius-server retransmit 12
switch_a(config)#


Port Authentication
Authentication State:
1. Command Mode: Interface mode
Logon to Configure Mode (Configure Terminal Mode).
Then logon to Interface mode.
fe1 means port 1.
The switch_a(config-if)# prompt will show on the screen.

switch_a(config)#interface fe1
switch_a(config-if)#