beautypg.com

Installation, Selecting a site for the ethernet extender switch, Din rail mounting – B&B Electronics EIRM-EXTEND-8 - Manual User Manual

Page 14: Electing a, Ite for the, Thernet, Xtender, Witch, Ounting

background image


8

Manual Documentation Number: EIRM-EXTEND-8-1411m

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com

B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com

Installation

Selecting a Site for the Ethernet Extender Switch


Ethernet Extender Switch should be installed in a location the meets the
following requirements:

The ambient temperature should be between -40°C to 75

℃ (-40℉ to

167

℉).


-The relative humidity should be less than 95 percent, non-condensing.

-Surrounding electrical devices should not exceed the electromagnetic field
(RFC) standards.

-Make sure that the Ethernet Extender Switch receives adequate ventilation.
Do not block the ventilation holes on each side of the Ethernet Extender
Switch.

Din Rail Mounting

Fix the DIN rail attachment plate to the back panel of the Hardened
Managed Ethernet Extender Switch.

Installation: Place the Hardened Managed Ethernet Extender Switch on
the DIN rail from above using the slot. Push the front of the Hardened
Managed Ethernet Extender Switch toward the mounting surface until
it audibly snaps into place.

Removal: Pull out the lower edge and then remove the Hardened
Managed Ethernet Extender Switch from the DIN rail.