Port


Configuration, Port Status, Rate Control, RMON Statistics, Per Port Vlan
Activities, Port Security

Configuration, Port Status, Rate Control, RMON Statistics, Per Port Vlan
Activities, Port Security

Configuration
Admin Setting:
1. Command Mode: Interface mode
Logon to Configure Mode (Configure Terminal Mode).
Then logon to Interface mode.
fe1 means port 1.
The switch_a(config-if)# prompt will show on the screen.

switch_a(config)#interface fe1
switch_a(config-if)#


2. Usage:
Use the shutdown command to shut down the selected interface.
Use the no shutdown to disable this function.

3. Command Syntax:
(no) shutdown

4. Example:
The following example shows the use of the shutdown command to shut
down the interface fe1 (port 1):

switch_a(config)#interface fe1
switch_a(config-if)#shutdown
switch_a(config-if)#


Duplex:
1. Command Mode: Interface mode
Logon to Configure Mode (Configure Terminal Mode).
Then logon to Interface mode.
fe1 means port 1.
The switch_a(config-if)# prompt will show on the screen.

switch_a(config)#interface fe1
switch_a(config-if)#


2. Usage: