beautypg.com

B&B Electronics EIRM-EXTEND-8 - Manual User Manual

Page 161

background image

Manual Documentation Number: EIRM-EXTEND-8-1411m

155

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com

B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com

switch_a(config-if)#dot1x port-control auto
switch_a(config-if)#


Periodic Reauthentication:
Reauthentication Period:
1. Command Mode: Interface mode
Logon to Configure Mode (Configure Terminal Mode).
Then logon to Interface mode.
fe1 means port 1.
The switch_a(config-if)# prompt will show on the screen.

switch_a(config)#interface fe1
switch_a(config-if)#


2. Usage:
Use this command to set the interval between reauthorization attempts.
Use no dot1x timeout re-authperiod command to delete the interval
between reauthorization attempts.

3. Command Syntax:
dot1x timeout re-authperiod SECS
no dot1x timeout re-authperiod
SECS <1-4294967295> Specify the seconds between reauthorization

attempts. The default time is 3600 seconds.


4. Example:
The following example specifies to set the interval 25 seconds between
reauthorization attempts:

switch_a(config)#interface fe1
switch_a(config-if)#dot1x timeout re-authperiod 25
switch_a(config-if)#