4. Example:
The following example enables link up trap for SNMP:

switch_a(config)#snmp-server trap-type enable linkUp
switch_a(config)#


SNMP v1/v2c
Get Community Name:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen.

switch_a(config)#


2. Usage:
Use snmp-server community get command to specify and no snmp-
server community get
command to remove get community name for
SNMP.

3. Command Syntax:
snmp-server community get NAME
no snmp-server community get
NAME The get community name for SNMP.

4. Example:
The following example specifies get community name (name) for SNMP:

switch_a(config)#snmp-server community get name
switch_a(config)#


Set Community Name:
1. Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen.

switch_a(config)#


2. Usage:
Use snmp-server community set command to specify and no snmp-
server community set
command to remove set community name for
SNMP.

3. Command Syntax:
snmp-server community set NAME
no snmp-server community set