beautypg.com

5 settings related to scanning, Settings related to scanning, R to – Fujitsu Ricoh Fujitsu fi-7280 Color Duplex Document Scanner User Manual

Page 183

background image

Chapter 9 Operational Settings

Appendix

Glossary

Introduction

Index

Contents

TOP

183

How to Load
Documents

Configuring the
Scan Settings

How to Use the
Operator Panel

Various Ways to
Scan

Daily Care

Troubleshooting

Replacing the
Consumables

Scanner
Overview

Operational
Settings

Adjusting the Position to Start the Scan
[Offset/Vertical magnification Adjustment]

When the output position of the scanned image is not correct or
the image appears shortened/elongated (vertically), adjust the
offset and the vertical magnification in the following procedure.

1

Start up the Software Operation Panel.

For details, refer to

"9.1 Starting Up the Software Operation Panel"

(page 163)

.

2

From the listing on the left, select [Device Setting] and
click the [Offset] button.

3

Adjust the level of offset/vertical magnification as needed.

9.5 Settings Related to Scanning

ATTENTION

Normally, you should not have to make any adjustments as the factory
default settings are configured at appropriate values.

Offset Setting

Description

Unit

Select [Flat bed] (fi-7260/fi-7280), [ADF (front)]
or [ADF (back)] as the target for offset
adjustment.

Main

Adjusts the horizontal (width) offset.
The value can range from -2 to +2 mm (in
increments of 0.5).

Sub

Adjusts the vertical (length) offset.
The value can range from -2 to +2 mm (in
increments of 0.5).