Page 358
334
Appendix E, Matrox MXO2 Specifications
$
BNC connector
$
Output impedance: 75
$
Nominal output level: 1V
p-p
• Balanced and unbalanced analog audio performance
$
Sampling frequency: 48 kHz (using 64x oversampling)
$
Quantization: 24 bits
$
S/N: > 85 db
$
THDN at 1 kHz, nominal level: < 0.05%
Environmental specifications
• Minimum/maximum room operating temperature
1
: 0 to 40º C
• Minimum/maximum storage temperature: –40 to 75º C
• Maximum altitude for operation: 3,000 meters
• Maximum altitude for transport: 12,000 meters
• Operating humidity: 20 to 80% relative humidity (non-condensing)
• Storage humidity: 5 to 95% relative humidity (non-condensing)
Matrox MXO2 Rack specifications
General
•
Video formats
NTSC, PAL, NTSC-EIAJ, 1080i/p/PsF, 720p, 576p, 480p
• Regulatory compliance
$
FCC Class A, CE Mark Class A, ACMA C-Tick Mark, VCCI
$
RoHS Directive 2002/95/EC
• Dimensions (without rackmount brackets)
$
Length
437 mm (17.2”)
$
Width
208 mm (8.2”)
$
Height
86 mm (3.4”) (two rack units)
• Dimensions (with rackmount brackets)
$
Length
483 mm (19”)
$
Width
208 mm (8.2”)
$
Height
89 mm (3.5”) (two rack units)
• AC power
$
100-240 VAC 50-60 Hz
1
This temperature range assumes that your Matrox MXO2 hardare doesn’t exceed the
maximum operating temperature as explained in