9 set logging default, Set logging default -12, Section 11.2.1.9 – Enterasys Networks 1G58x-09 User Manual
Page 482
Logging and Network Management Command Set
Configuring System Logging
11-12
Matrix E1 Series (1G58x-09 and 1H582-xx) Configuration Guide
Syntax Description
None.
Command Defaults
None.
Command Type
Switch command.
Command Mode
Read-Only.
Example
This command shows how to display the Syslog server default values. For an explanation of the
command output, refer back to
11.2.1.9 set logging default
Use this command to set logging default values.
set logging default {facility facility | severity severity | port port}
Matrix>show logging default
Facility Severity Port
-----------------------------------------------------------
Defaults: local7 warnings(5) 514
NOTE: Most system messages are logged at severity level of 6 (Notice). By default,
the logging applications are set to 5 (Warning),
which will suppress level 6 (Notice)
messages from the console session. To view most of the logging of configuration
messages on the console session, ACL hits etc., the set logging application
command should be used as described in
to set the logging level for
applications to 6 or higher.