2 set vlan classification, Set vlan classification -25, Sification – Enterasys Networks 1G58x-09 User Manual
Page 367: Section 7.3.5.2
VLAN Configuration Command Set
Assigning VLANs According to Classification Rules
Matrix E1 Series (1G58x-09 and 1H582-xx) Configuration Guide
7-25
Syntax Description
None.
Command Defaults
None.
Command Type
Switch command.
Command Mode
Read-Only.
Command Alternative (v2.05.xx and higher)
show policy class (
Example
This example shows that the VLAN classification function is enabled, and that two VLAN
classifications have been configured on the device:
7.3.5.2
set vlan classification
Use this command to
•
assign or contain frames according to classification rule,
•
enable or disable the global classifier on the device,
•
create a rule that will assign untagged traffic to a VLAN based on Layer 2/3/4 classification
rules, and
•
enable or disable a classification rule associated with a VLAN.
Matrix>show vlan classification
VLAN Classification enabled.
Vlan Classification Entries
--------------------------------
Vlan ID: 5, Src UDP Range: 45-53, Status: enabled,
Action Status: Forward No Frames
Port List: None
----------
Vlan ID: 7, Ethernet II Type: IP, Status: enabled,
Action Status: Forward All Frames
Port List: None