Enterasys Networks 1G58x-09 User Manual
Page 330
Spanning Tree Configuration Command Set
Reviewing and Setting Spanning Tree Port Parameters
6-44
Matrix E1 Series (1G58x-09 and 1H582-xx) Configuration Guide
Syntax Description
Command Defaults
If sid is not specified, SID 0 will be assumed.
Command Type
Switch command.
Command Mode
Read-Write.
Example
This example shows how to set port cost to 25 on Fast Ethernet front panel port 11:
port-string
Specifies the port(s) to which to assign a cost value. For a
detailed description of possible port-string values, refer to
.
cost
Specifies a cost value. Ranges are:
•
0 to 65535 with legacy path cost enabled.
•
0 to 200000000 with legacy path cost disabled.
NOTES: A cost value of 0 will allow a port’s default
cost, which is based on link speed, to be used.
If the link is part of a trunk, the sum of all link
speeds in the trunk should be used as the cost
value.
For details on the set legacypathcost command,
.
sid
(Optional) Sets a cost value for a specific SID.
Matrix>set spantree portcost fe.0.11 25