4 show port ingress filter, Show port ingress filter -16, Section 7.3.3.4 – Enterasys Networks 1G58x-09 User Manual
Page 358
VLAN Configuration Command Set
Assigning Port VLAN IDs (PVIDs) and Ingress Filtering
7-16
Matrix E1 Series (1G58x-09 and 1H582-xx) Configuration Guide
7.3.3.4
show port ingress filter
Use this command to show all ports that are enabled for port ingress filtering, which limits incoming
VLAN ID frames according to a port VLAN egress list. If the port is not on the port VLAN egress
list of the VLAN ID indicated in the incoming frame, then that frame is dropped and not forwarded.
The device port ingress list is created using the set port ingress command described in
.
show port ingress filter [port-string]
Syntax Description
Command Defaults
If port-string is not specified, ingress filtering status for all ports will be displayed.
Command Type
Switch command.
Command Mode
Read-Only.
Example
This example shows how to display the port ingress filter status to see which of the front panel ports
10 through 15 are enabled or disabled for port ingress filtering:
port-string
(Optional) Displays ingress filtering status for specific
port(s). For a detailed description of possible port-string
values, refer to
.
Matrix>show port ingress filter fe.0.10-15
Port State
-------- ---------
fe.0.10 disabled
fe.0.11 disabled
fe.0.12 disabled
fe.0.13 disabled
fe.0.14 disabled
fe.0.15 disabled