beautypg.com

1 show vlan classification, Show vlan classification -24, Section 7.3.5 – Enterasys Networks 1G58x-09 User Manual

Page 366

background image

VLAN Configuration Command Set

Assigning VLANs According to Classification Rules

7-24

Matrix E1 Series (1G58x-09 and 1H582-xx) Configuration Guide

7.3.5

Assigning VLANs According to Classification Rules

Purpose

To perform the following:

Assign incoming untagged frames to a specific VLAN according to the parameters in created
classification rules. Only untagged frames are classified.

Drop untagged frames according to a VLAN based on Layer 2/3/4 of a received frame.

Display the VLAN ID (VID), protocol classification, and description of each classification of
the current entries.

Add/delete a VID and associated classification entry.

Commands

The commands used to assign VLANs to classification rules are listed below and described in the
associated section as shown.

show vlan classification (

Section 7.3.5.1

)

set vlan classification (

Section 7.3.5.2

)

clear vlan classification (

Section 7.3.5.5

)

set vlan classification ingress (

Section 7.3.5.6

)

clear vlan classification ingress (

Section 7.3.5.7

)

7.3.5.1

show vlan classification

Use this command to display the VLAN ID (VID), protocol classification, and description of each
classification of the current entries.

show vlan classification

Important Notice

In addition to the commands described in this section, Matrix E1 (1G58x-09 and 1H582-xx)
devices with firmware versions 2.05.xx and higher also support policy profile-based classification
to a VLAN or Class of Service. Policy classification commands that can be used alternatively to
VLAN classification commands are noted in the appropriate sections under the heading
“Command Alternative (v2.05.xx and higher)”. For a description of the complete policy
classification command set, refer to

Chapter 8.

This manual is related to the following products: