Pac208/216 basic troubleshooting, Pac208/216 basic troubleshooting -8, Chapter 4 troubleshooting – Grass Valley PDR 200 Service Manual User Manual
Page 58

Chapter 4 Troubleshooting
4-8
PDR 200 Service Manual
PAC208/216 Basic Troubleshooting
Table 4-2 identifies basic symptoms for the PAC208/216.
Table 4-2. PAC208/216 Basic Troubleshooting
Symptom
Possible Cause
Corrective Action
LED off, fan is on.
LED and cable bad.
Replace LED and cable
Fan is off, power LED on.
Fan bad.
Replace fan.
LED is off, fan is off when switch is on.
1. Power supply bad.
Replace power supply.
2. Switch or switch cable bad.
Replace switch and cable.
3. Line filter bad.
Replace power connector/line filter
4. Power cord bad
Replace power cord.
See also other documents in the category Grass Valley Equipment:
- LDK 5302 (24 pages)
- SFP Optical Converters (18 pages)
- 2000GEN (22 pages)
- 2011RDA (28 pages)
- 2010RDA-16 (28 pages)
- 2000NET v3.2.2 (72 pages)
- 2000NET v3.1 (68 pages)
- 2020DAC D-To-A (30 pages)
- 2000NET v4.0.0 (92 pages)
- 2020ADC A-To-D (32 pages)
- 2030RDA (36 pages)
- 2031RDA-SM (38 pages)
- 2041EDA (20 pages)
- 2040RDA (24 pages)
- 2041RDA (24 pages)
- 2042EDA (26 pages)
- 2090MDC (30 pages)
- 2040RDA-FR (52 pages)
- LDK 4021 (22 pages)
- 3DX-3901 (38 pages)
- LDK 4420 (82 pages)
- LDK 5307 (40 pages)
- Maestro Master Control Installation v.1.5.1 (455 pages)
- Maestro Master Control Installation v.1.5.1 (428 pages)
- 7600REF Installation (16 pages)
- 7600REF (84 pages)
- 8900FSS (18 pages)
- 8900GEN-SM (50 pages)
- 8900NET v.4.3.0 (108 pages)
- Safety Summary (17 pages)
- 8900NET v.4.0.0 (94 pages)
- 8906 (34 pages)
- 8911 (16 pages)
- 8900NET v.3.2.2 (78 pages)
- 8914 (18 pages)
- 8912RDA-D (20 pages)
- 8916 (26 pages)
- 8910ADA-SR (58 pages)
- 8920ADC v.2.0 (28 pages)
- 8920ADC v.2.0.1A (40 pages)
- 8920DAC (28 pages)
- 8920DMX (30 pages)
- 8920ADT (36 pages)
- 8920MUX (50 pages)
- 8921ADT (58 pages)