Table 2-5. Program Input Genlock
Characteristics
Description
Burst Frequency Lock Range
Requirement:
±
50 Hz at subcarrier
Supplemental Data:Remains locked or initial lock
Signal Amplitude Lock
Range
Requirement:
Stays locked to +6 dB and -3 dB
Phase Jitter (Analog Input and
Analog Output)
Requirement:
≤
1
°
Phase Jitter (Analog Output
Only)
Requirement:
≤
0.5
°
Hum Rejection
Requirement:
≥
32 dB
Recovery Time
Requirement:
Fast - Within 35.7 mV in 2 to 3 lines
Medium - Within 35.7 mV in 10 to 30 lines
Slow - Within 35.7 mV in > 30 lines
Switch Points
Requirement:
Fast - Medium 30 to 40 dB signal-to-noise
Supplemental Data:Medium - Slow 20 to 30 dB signal-to-noise
Table 2-6. Analog Input/Output
Characteristics
Description
Program Input Return Loss
Requirement:
≥
40 dB to 5 MHz
Program Output Return Loss
Requirement:
≥
40 dB to 5 MHz
Table 2-7. Component Analog Video Input
Characteristic
Specification
Input connectors:
BNCx (3) terminating
Impedance:
75 ohms
Return loss:
≤
-40dB to 5.0MHz
Input formats
supported (525/60):
Betacam
Betacam without setup
Betacam (non-EBU)
MII
MII without setup (SMPTE/EBU-N10)
GBR (700mv no setup)
Input formats
supported (625/50):
SMPTE/EBU-N 10
Betacam (non-EBU)
GBR (700mv no setup)
Reference: