beautypg.com

Chapter 2 specifications – Grass Valley PDR 200 Service Manual User Manual

Page 26

background image

Chapter 2 Specifications

2-6

PDR 200 Service Manual

Table 2-5. Program Input Genlock

Characteristics

Description

Burst Frequency Lock Range

Requirement:

±

50 Hz at subcarrier

Supplemental Data:Remains locked or initial lock

Signal Amplitude Lock
Range

Requirement:

Stays locked to +6 dB and -3 dB

Phase Jitter (Analog Input and
Analog Output)

Requirement:

1

°

Phase Jitter (Analog Output
Only)

Requirement:

0.5

°

Hum Rejection

Requirement:

32 dB

Recovery Time

Requirement:

Fast - Within 35.7 mV in 2 to 3 lines
Medium - Within 35.7 mV in 10 to 30 lines
Slow - Within 35.7 mV in > 30 lines

Switch Points

Requirement:

Fast - Medium 30 to 40 dB signal-to-noise

Supplemental Data:Medium - Slow 20 to 30 dB signal-to-noise

Table 2-6. Analog Input/Output

Characteristics

Description

Program Input Return Loss

Requirement:

40 dB to 5 MHz

Program Output Return Loss

Requirement:

40 dB to 5 MHz

Table 2-7. Component Analog Video Input

Characteristic

Specification

Input connectors:

BNCx (3) terminating

Impedance:

75 ohms

Return loss:

-40dB to 5.0MHz

Input formats
supported (525/60):

Betacam
Betacam without setup
Betacam (non-EBU)
MII
MII without setup (SMPTE/EBU-N10)
GBR (700mv no setup)

Input formats
supported (625/50):

SMPTE/EBU-N 10
Betacam (non-EBU)
GBR (700mv no setup)

Reference:

Sync on Y/G video input