Rear Panel Indicators and Control

PDR200 Service Manual

4-7

DISK RECORDER Master/Slave - The red LEDs on these boards flash On at power
up and should then go Off.

If LED does not flash or remains On:

- Check the Profile.log to ensure the system sees the board and replace board

if it doesn’t.

- Run board diagnostics for appropriate board.

If the LED on the Master Enhanced Disk Recorder (MEDR) board remains On:

- The 27 MHz clock from the Reference Generator board may be missing, run

diagnostics for the MEDR and the Reference Genlock boards.

Serial Digital Component VIDEO I/O - The red LED on this board flashes On at
power up and should then go Off.

If LED does not flash or remains On:

- Check the Profile.log to ensure the system sees the board and replace board

if it doesn’t.

- Run board diagnostics.

AUDIO I/O Digital AES/EBU - The red LED on this board flashes On at power up
and should then go Off.

If LED does not flash or remains On:

- Check the Profile.log to ensure the system sees the board and replace board

if it doesn’t.

- Run board diagnostics.

REFERENCE Analog Video - The red LED on this board flashes On at power up
and should then go Off.

If LED does not flash or remains On:

- Check the Profile.log to ensure the system sees the board and replace board

if it doesn’t.

- Run board diagnostics.

NOTE: If the LEDs on all boards remain Off or On, reload CMOS and reboot.