Environmental criteria, Mechanical specifications – Grass Valley PDR 200 Service Manual User Manual
Page 31

Environmental Criteria
PDR200 Service Manual
2-11
Environmental Criteria
Table 2-16 lists the environmental criteria for the PDR200/PAC208/216.
Mechanical Specifications
Table 2-17 lists the PDR200 mechanical specifications and Figure 2-1 shows the
dimensions as listed in Table 2-17.
Table 2-16. Environmental Criteria
Characteristics
Description
Operating Temperature
Requirement:
5
°
to 40
°
C (+41
°
to 122
°
F)
Storage Temperature
Requirement:
-40
°
to 65
°
C (-40
°
to 149
°
F)
Operating Altitude
Requirement:
To 15,000 feet (4572 meters)
Supplemental Data:IEC 950 compliant to 2000 meters
Storage Altitude
Requirement:
To 50,000 feet (15,240 meters)
Mechanical Shock
Mil Specification: Mil-T-28800D, Class 6 (Non-Operating Only)
Transportation
Requirement:
Qualified under NSTA Test Procedure 1A, Category II (24 inch drop)
Equipment Type
Supplemental Data:Information Technology
Equipment Class
Supplemental Data:Class I
Installation Category
Requirement:
Category II Local level, appliances, portable equipment, etc.
Pollution Degree
Requirement:
Level 2 Normally only non-conductive pollution occurs. Occasionally a
temporary conductivity caused by condensation must be expected.
Humidity
Requirement:
Operating 20% - 80%
Non-Operating 8% - 90%
Transportation 5% - 95%
Maximum Wet Bulb Temperature 26
°
Supplemental Data:Do not operate with visible moisture on the circuit boards
Table 2-17. PDR 200 Mechanical Specifications
Characteristic
Description
Dimensions
Requirement:
Height: 8.720 inches(22.149 centimeters)
Width: 19.000 inches (48.260 centimeters)
Depth: 24.150 inches (61.341 centimeters)
Weight
Requirement:
Net: 70 pounds (31.818kilograms)
Shipping: 85 pounds (38.636 kilograms)