Chapter 6: Optional Equipment Installation
The solenoid valve assembly consists of two independent valves (Valve #1 and Valve #2) on a
common manifold. The manifold supplies air at the user’s line pressure (28 psi minimum
(0.19 MPa) to 114 psi (0.786 MPa) maximum). Each valve has two output ports, A and B. The
output ports are arranged so that when Port A is pressurized, Port B is not pressurized.
Conversely, when Port B is pressurized, Port A is not. In the Adept Cobra s-series robots, the
air lines from Port A on each valve are plugged at the factory (at the solenoid assembly).
The Solenoid Kit for the Adept Cobra s-series robot is available through Adept. Contact your
Adept Sales Representative for current price and availability.
Table 6-6. Air Pressure
Air Pressure (PSI)
Air Pressure (MPa)
28 - 114
0.19 - 0.786
Tools Required
l
Assorted hex drivers
l
Cable ties
l
Diagonal wire cutters
l
Solenoid Valve Upgrade Kit (Adept p/n 02853-000)
Procedure
1. Turn off all power to the robot.
2. Remove three screws on each side of the outer link cover. Remove two screws on top
and remove the cover.
For the IP-65 version, refer to Removing/Installing Outer Link Cover on page 128.
3. Connect the Internal Solenoid Valve Cable assembly to the Solenoid Manifold assembly,
by plugging the SOL 1 connector into Valve 1 and SOL 2 into Valve 2.