Chapter 9: IP-65 Option
3. Insert the housing into the Cable Entry Housing Cover, and fasten with the lock nut.
Tighten the lock nut securely.
4. Pull all of the cables through the Roxtec Cable Seal Assembly.
5. Temporarily remove the pressure screw, slip washer, and washer.
6. Adapt the modules which are to hold cables by peeling layers until you obtain the gap
shown in 7, above.
7. There must be a 0.1 - 1.0 mm gap between the two module halves
when held against the cables.
Adept Cobra s800 Inverted Robot User's Guide, Rev H1