Chapter 9: IP-65 Option

Pressurizing the Robot

The user must supply compressed air to maintain positive air pressure inside the robot.

1. Remove the shipping plug from the compressed air fitting located just above the

AIB/eAIB. See Figure 9-8.

Figure 9-8. Compressed Air Fitting on Robot

2. Connect a compressed air source to the air fitting. The specification for the regulated air

supply is shown in the following table.

Table 9-1. Compressed Air Specifications

Required Air Pressure

Required Air Flow, Minimum

3 bar, ± 10%

(44 PSI, ± 10%)

57 liters per minute

(2 cubic feet per minute)

CAUTION: The compressed air supply must be clean
and dry and it must be on continuously to maintain a
positive air pressure inside the robot. Failure to do this
could result in moisture or particle buildup inside the
robot and lead to reduced performance or damage to the
robot. This will also void your warranty.