Chapter 6: Optional Equipment Installation

Table 6-5. ESTOP Connector

Pin #

Description

Pin Location

1

ESTOP_INPUT

1

2

ESTOP Connector

as viewed on robot

2

24 V

Mating Connector:
AMP/Tyco #172165-1, 2-pin Mini-Universal Mate-N-Lock
AMP/Tyco #770985-1, Pin Contact, Mini-Univ. Mate-N-Lok

Pin 1

Pin 2

User-supplied normally-closed contact.
Can be connected to a break-away sensor
to cause an E-Stop condition when circuit
is open.

Note: This function is disabled by default - it must
be enabled in software.

Typical ESTOP
Connector Circuit

Figure 6-8. Internal E-Stop Connector Circuit

NOTE: This circuit will trigger an emergency stop of the local robot only. It does not
link to the E-Stop chain of the host SmartController.

Procedure to Enable Break-away E-Stop Function

To enable the Break-away E-Stop function, you have to use the Adept ACE software to change
the default configuration:

NOTE: This requires that you have Expert access.

From the Adept ACE software:

To get into Expert mode:

1. Click on Object.

2. Click Expert Access.

You will be asked for a password, to enter Expert Access.

3. Enter the Expert Access password.

To change the Break-away E-Stop parameter:

Adept Cobra s800 Inverted Robot User's Guide, Rev H1