Chapter 4: System Operation

0.7 A of current. This driver has overtemperature protection, shorted-load protection, and is
current limiting. In the event of an output short or other overcurrent situation, the affected
output of the driver IC turns off and back on automatically to reduce the temperature of the IC.
The driver draws power from the primary 24 VDC input to the robot through a self-resetting
polyfuse.

The outputs are accessed through direct connection to the XIO connector (see Table 4-5), or
through the optional XIO Termination Block. See the documentation supplied with the
Termination Block for details.

XIO Output Specifications

Table 4-7. XIO Output Circuit Specifications

Parameter

Value

Power supply voltage range

See Table 3-2.

Operational current range, per
channel

I

out

700 mA

Total Current Limitation, all
channels on

I

total

1.0 A @ 50° C ambient

I

total

1.5 A @ 25° C ambient

On state resistance (I

out

= 0.5 A)

R

on

0.32

@ 85

°

C

Output leakage current

I

out

25 µA

Turn-on response time

125 µsec max., 80 µsec typical
(hardware only)

Turn-off response time

60 µsec. max., 28 µsec typical
(hardware only)

Output voltage at inductive load
turnoff (I

out

= 0.5 A, Load = 1 mH)

(+V - 65)

 V

demag

(+V - 45)

DC short circuit current limit

0.7 A

I

LIM

2.5 A

Peak short circuit current

I

ovpk

4 A

Adept Cobra s800 Inverted Robot User's Guide, Rev H1

Page 49 of 142