Chapter 6: Optional Equipment Installation

Figure 6-4. User Connectors on standard Joint 2. IP-65 Joint 2 on right.

NOTE: The connectors shown in Figure 6-4 are not available on the outside of this
link for the IP-65 version Cobra s800 Inverted. Refer to User Connectors on page
133
.

NOTE: See Connecting Digital I/O to the System on page 43 for information on the
IO Blox connector. Also refer to the

Adept IO Blox User's Guide

for details.

User Electrical Lines

There is a 25-pin male connector (24 conductor) on the robot user panel on the back of Joint 1
for user electrical lines (see Figure 6-3). This connector is wired directly to a 25-pin female
connector on the top of the outer link (see Figure 6-4). These connectors can be used to run user
electrical signals from the user panel, through the robot, and up to the outer link.

NOTE: The connectors shown in Figure 6-4 are not available on the outside of this
link for the IP-65 version of the Cobra s800 Inverted. Refer to User Connectors on
page 133
.

Wire Specifications: Wire size: 0.1 mm

2

(27 AWG), Pin Numbers 1-24, 12 pairs, twisted in

pairs as 1&2, 3&4, 5&6, .... 23&24. Maximum current per line: 1 Amp.

6.4 Internal User Connectors