EOAPWR Connector

This 4-pin connector (see the following table) provides 24 VDC power and ground for user
applications. See the following table for the pinouts and Table 6-4 for the output specifications.

Table 6-3. EOAPWR Connector Pinout

Pin #

Description

Pin Location

1

24 VDC (see Table 6-4 for
current specs)

1

2

4

3

EOAPWR Connector

as viewed on robot

2

Ground

3

24 VDC (see Table 6-4 for
current specs)

4

Ground

Mating Connector:
AMP/Tyco #172167-1, 4-pin Mini-Universal Mate-N-Lok
AMP/Tyco #770985-1, Pin Contact, Mini-Univ. Mate-N-Lok