Page 118
Chapter 8: Cleanroom Robots
8.2 Connections
Figure 8-2. Cleanroom Connections
The connection panel for Cleanroom robots is modified to accommodate the vacuum lines
needed. Users will still have use of the two 6 mm and three 4 mm air lines, as well as the I/O
connections and DeviceNet port.
The 3/4 in. vacuum fitting is a high-flow/low-vacuum port. The 3/8 in. vacuum fitting is used
to evacuate the bellows area of the robot.
8.3 Requirements
Table 8-1. Cleanroom Robot Requirements
Vacuum Source
Recommended Volumetric Flow
Rate
a
3/4 inch NPT (female) fitting
at the back of the robot
0.20 m
3
/min (7 ft
3
/min) @
0.3 inHg (1.0 kpa) pressure
3/8 inch NPT (female) fitting
at the back of the robot
0.05 m
3
/min (1.6 ft
3
/min) @ 18
inHg (61.0 kpa) pressure
Quill inside diameter
The inside diameter of the quill must be plugged by the user’s
end-effector in order for sufficient vacuum to develop in the
outer link.
a
The vacuum lines provided must maintain the listed vacuums, as measured at the robot,
when the robot and vacuum lines are connected. Adept recommends that you install in-line
vacuum gauges at the robot.
Adept Cobra s800 Inverted Robot User's Guide, Rev H1