Chapter 8: Cleanroom Robots

8.2 Connections

Figure 8-2. Cleanroom Connections

The connection panel for Cleanroom robots is modified to accommodate the vacuum lines
needed. Users will still have use of the two 6 mm and three 4 mm air lines, as well as the I/O
connections and DeviceNet port.

The 3/4 in. vacuum fitting is a high-flow/low-vacuum port. The 3/8 in. vacuum fitting is used
to evacuate the bellows area of the robot.

8.3 Requirements

Table 8-1. Cleanroom Robot Requirements

Vacuum Source

Recommended Volumetric Flow
Rate

a

3/4 inch NPT (female) fitting
at the back of the robot

0.20 m

3

/min (7 ft

3

/min) @

0.3 inHg (1.0 kpa) pressure

3/8 inch NPT (female) fitting
at the back of the robot

0.05 m

3

/min (1.6 ft

3

/min) @ 18

inHg (61.0 kpa) pressure

Quill inside diameter

The inside diameter of the quill must be plugged by the user’s
end-effector in order for sufficient vacuum to develop in the
outer link.

a

The vacuum lines provided must maintain the listed vacuums, as measured at the robot,

when the robot and vacuum lines are connected. Adept recommends that you install in-line
vacuum gauges at the robot.

Adept Cobra s800 Inverted Robot User's Guide, Rev H1