beautypg.com

Can 1 message center 14 control register (c1m14c), Can 1 message center 15 control register (c1m14c), Can 1 m – Maxim Integrated High-Speed Microcontroller Users Guide: DS80C390 Supplement User Manual

Page 90: Essage, Enter, 14 c, Ontrol, Egister, C1m14c), 15 c

background image

High-Speed Microcontroller User’s Guide: DS80C390 Supplement

90 of 158

CAN 1 MESSAGE CENTER 14 CONTROL REGISTER (C1M14C)

7 6 5 4 3 2 1 0

SFR FEh

MSRDY

ETI

ERI

INTRQ

EXTRQ

MTRQ ROW/TIH

DTUP

RW-0 RW-0 RW-0 RW-0 RC-0 R*-0 R*-0 R*-0

R = Unrestricted Read, C = Clear Only, * = See description below, -n = Value after Reset

C1M14C
Bits 7-0

Operation of the bits in this register are identical to those found in the CAN 1
Message One Control Register (C1M1C;ABh). Please consult the description
of that register for more information.

CAN 1 MESSAGE CENTER 15 CONTROL REGISTER (C1M14C)

7 6 5 4 3 2 1 0

SFR FFh

MSRDY

ETI

ERI

INTRQ

EXTRQ

MTRQ ROW/TIH

DTUP

RW-0 RW-0 RW-0 RW-0 RC-0 R*-0 R*-0 R*-0

R = Unrestricted Read, C = Clear Only, * = See description below, -n = Value after Reset

C1M15C
Bits 7-0

Operation of the bits in this register are identical to those found in the CAN 1
Message One Control Register (C1M1C;ABh). Please consult the description
of that register for more information.