High-Speed Microcontroller User’s Guide: DS80C390 Supplement

18 of 158

TIMER/COUNTER CONTROL (TCON)

7 6 5 4 3 2 1 0

SFR

88h

TF1 TR1 TF0 TR0 IE1 IT1 IE0 IT0

RW-0 RW-0 RW-0 RW-0 RW-0 RW-0 RW-0 RW-0

R = Unrestricted Read, W = Unrestricted Write, -n = Value after Reset

TF1
Bit 7

Timer 1 Overflow Flag.

This bit indicates when Timer 1 overflows its

maximum count as defined by the current mode. This bit can be cleared by
software and is automatically cleared when the CPU vectors to the Timer 1
interrupt service routine.
0 = No Timer 1 overflow has been detected.
1 = Timer 1 has overflowed its maximum count.

TR1
Bit 6

Timer 1 Run Control.

This bit enables/disables the operation of Timer 1.

0 = Timer 1 is halted.
1 = Timer 1 is enabled.

TF0
Bit 5

Timer 0 Overflow Flag.

This bit indicates when Timer 0 overflows its

maximum count as defined by the current mode. This bit can be cleared by
software and is automatically cleared when the CPU vectors to the Timer 0
interrupt service routine or by software.
0 = No Timer 0 overflow has been detected.
1 = Timer 0 has overflowed its maximum count.

TR0
Bit 4

Timer 0 Run Control.

This bit enables/disables the operation of Timer 0.

0 = Timer 0 is halted.
1 = Timer 0 is enabled.

IE1
Bit 3

Interrupt 1 Edge Detect.

This bit is set when an edge/level of the type defined

by IT1 is detected. If IT1=1, this bit will remain set until cleared in software or
the start of the External Interrupt 1 service routine. If IT1=0, this bit will
inversely reflect the state of the

1

INT pin.

IT1
Bit 2

Interrupt 1 Type Select.

This bit selects whether the

1

INT pin will detect edge

or level triggered interrupts.

0 =

1

INT is level triggered.

1 =

1

INT is edge triggered.

IE0
Bit 1

Interrupt 0 Edge Detect.

This bit is set when an edge/level of the type defined

by IT0 is detected. If IT0=1, this bit will remain set until cleared in software or
the start of the External Interrupt 0 service routine. If IT0=0, this bit will
inversely reflect the state of the

0

INT pin.

IT0
Bit 0

Interrupt 0 Type Select.

This bit selects whether the

0

INT pin will detect edge

or level triggered interrupts.
0 =

0

INT is level triggered.

1 =

0

INT is edge triggered.