beautypg.com

No ppp time-btwn-reconnect, No ppp username, No schedule-availability – Carrier Access Adit 3000 Series and Multi-Service Router (MSR) Card none User Manual

Page 397: No shutdown

background image

Adit 3000 (Rel. 1.6) and MSR Card (Rel 2.0) CLI

17-19

Configuration - PPTPC Mode

no ppp time-btwn-reconnect

Use the PPTP Client no ppp time-btwn-reconnect command to set the time between reconnect
attempts to the default setting. To configure the time between reconnect attempts, see ppp time-
btwn-reconnect
command on page 17-22
.

Syntax:

(config-pptpc-{n})# no ppp time-btwn-reconnect

Example:

(config-pptpc-1)# no ppp time-btwn-reconnect

Supported Platforms:

Adit 3104, Adit 3200, Adit 3500, MSR

no ppp username

Use the PPTP Client no ppp username command remove the PPP username.

To set a PPP user, see

ppp username command on page 17-22.

Syntax:

(config-pptpc-{n})# no ppp username

username

Example:

(config-pptpc-1)# no ppp username test-user-name

Supported Platforms:

Adit 3104, Adit 3200, Adit 3500, MSR

no schedule-availability

Use the PPTP Client no schedule-availability command to disable a schedule rule

.

To add a rule,

see schedule-availability command on page 17-23.

Syntax:

(config-pptpc-{n})# no schedule-availability

Example:

(config-pptpc-1)# no schedule-availability

Supported Platforms:

Adit 3104, Adit 3200, Adit 3500, MSR

no shutdown

Use the PPTP Client no shutdown

command to set the interface up (In-Service)

.

To set the interface

down (Out-of-Service), see shutdown command on page 17-23.

Syntax:

(config-pptpc-{n})# no shutdown

Example:

(config-pptpc-1)# no shutdown

Supported Platforms:

Adit 3104, Adit 3200, Adit 3500, MSR