TruVision DVR 42 User Manual
Wiring the KTD-405 keypad
The KTD-405 keypad uses RS-485 simplex wiring. The signal is transferred by a
single twisted pair line. A shielded STP CAT5 network cable is recommended.
Ground one end of the cable, either the first or last device on the RS-485 line.
The maximum number of devices that can be installed in one bus is 255, with a
maximum cable length of 1200 m. The cable length can be expanded using a
signal distributor.
Both the first and the last device in series should be terminated with 120 Ohm
resistance to minimize line reflections. See Figure 5 below.
Figure 5: RS-485 bus serial wiring
1. Keypad (KTD-405 keypad shown)
2. I/O box
3. See section “RS-485 ports” on page 9
Use an RS-485 signal distributor for a star wiring configuration. See Figure 6 on
page 17.