SECTION V CARE OF YOUR MACHINE

Care of Your Machine

CAUTION:

Before performing any of the following, make sure

that the sewing machine is unplugged from the

power source.

The Kenmore 19000 has been specifically designed and

manufactured to give you a lifetime of trouble-free

sewing. The bobbin area and hook race should be

cleaned after completion of every garment. Do not

store the machine in a high-humidity area, near a heat

radiator or in direct sunlight. Clean the outside of the

machine with a soft cloth and neutral soap. Press the

up/down needle button to raise the needle and unplug

the machine before cleaning.

♦ Cleaning the Bobbin Holder

Loose threads and dust may cause puckered stitches

and thread breakage during stitching. Check for lint

build-up after each garment is completed.

Turn off the power switch and unplug the machine.

Remove the cover plate by sliding the hook cover

plate release bunon to the right.

Take out the bobbin to brush out dust and lint.

(You may also use a small vacuum cleaner.)

Insert the bobbin and attach the hook cover plate.

♦ Exposing the Hook Race

Unplug the machine and remove the presser foot

and needle.

Remove the screw on the left side of the needle

plate with the screwdriver.

Remove the needle plate and take out the bobbin.

Lift up the bobbin holder and remove it.