beautypg.com

Ppendix, Power module-dependent parameter default values – Rockwell Automation Liqui-Flo AC GP Vector Drive Version 6.4 User Manual

Page 193

background image

Power Module-Dependent Parameter Default Values

C-1

A

PPENDIX

C

Power Module-Dependent

Parameter Default Values

Second Menu General Parameters (USA Defaults)

Second Menu Volts/Hertz Parameters (USA Defaults)

Second Menu Vector Parameters (USA Defaults)

Parameter

Number

Parameter Name

B-Frame

C-Frame

D-Frame

41L4060

41LR4060

50LW4060

50LR4060

64LW4060

64LR4060

120L4060

P.047

Carrier Frequency (kHz)

2

2

2

2

Parameter

Number

Parameter Name

B-Frame

C-Frame

D-Frame

41L4060

41LR4060

50LW4060

50LR4060

64LW4060

64LR4060

120L4060

H.002

Motor Nameplate Amps

386.0

500.0

643.0

1157.0

Parameter

Number

Parameter Name

B-Frame

C-Frame

D-Frame

41L4060

41LR4060

50LW4060

50LR4060

64LW4060

64LR4060

120L4060

U.004

Motor Nameplate Amps

386.0

500.0

643.0

1157.0

U.005

Motor Nameplate RPM

1785

1785

1785

1785

U.006

Magnetizing Current

35.0

35.0

35.0

35.0

U.012

Speed Regulator Proportional Gain

10.00

10.00

10.00

10.00

U.013

Speed Regulator Integral Gain

5.00

5.00

5.00

5.00

U.014

Torque Regulator Proportional Gain

0.20

0.20

0.20

0.20

U.015

Torque Regulator Integral Gain

100.0

100.0

100.0

100.0

U.016

Field Weakening Start RPM

1785

1785

1785

1785

U.017

Motor Top Speed

1785

1785

1785

1785

U.019

Flux Current Regulator Proportional
Gain

0.15

0.15

0.15

0.15

U.021

Rotor Time Constant

350

350

350

350

U.022

Motor Nameplate HP

350.0

450.0

600.0

1000.0

U.032

SVC Flux Current Regulator Gain

350

300

300

300