U.019 flux current regulator proportional gain, U.020 flux current regulator integral gain, U.021 rotor time constant – Rockwell Automation Liqui-Flo AC GP Vector Drive Version 6.4 User Manual
Page 161

Programming Reference
4-79
Note that this parameter is not used in version 6.0 but is reserved for future
enhancements.
U.019 Flux Current Regulator Proportional Gain
This parameter
determines the
performance of the
magnetizing current
regulator.
For most
applications, it is
recommended that
this parameter not be
changed.
Parameter Range:
0.10 to 31.99
Default Setting:
Power Module-dependent, see Appendix C
Parameter Type:
Tunable
Refer also to parameters:
U.020 Flux Current Regulator Integral Gain
U.020 Flux Current Regulator Integral Gain
This parameter
determines the
performance of the
magnetizing current
regulator.
For most
applications, it is
recommended that
this parameter not be
changed.
Parameter Range:
10.0 to 628.0 radians/second
Default Setting:
50.0
Parameter Type:
Tunable
Refer also to parameters:
U.019 Flux Current Regulator Proportional Gain
U.021 Rotor Time Constant
This parameter
determines the
performance of the
magnetizing current
regulator.
For most
applications, it is
recommended that
this parameter not be
changed.
Parameter Range:
100 to 9999 milliseconds
Default Setting:
Power Module-dependent, see Appendix C
Parameter Type:
Tunable
Refer also to parameters:
N/A