P.00i, P.002 – Rockwell Automation Liqui-Flo AC GP Vector Drive Version 6.4 User Manual

Page 15

background image

Starting Up the Drive for Volts/Hertz Regulation

1-5

Step 3.3 Press the ENTER key to display the default setting of P.001.

This displays the default setting for
acceleration time (20.0 seconds).

Step 3.4 Press the ▲

key to increase acceleration time, or the ▼ key to decrease

acceleration time

.

The adjustment range is:

1.0 to 999.9 seconds.

VALUE ENTERED:

Step 3.5 Press the ENTER key to save the changed value.

After pressing ENTER, the same
parameter number is displayed. You can
now go to the next parameter.

Step 3.6 Press the ▲

key to display P.002, Decel Time 1 (RAMP 1).

This parameter sets the deceleration
time in seconds. The default stop
method is coast-to-stop, set in P.025.

20.0

Forward
Reverse

AUTO

MAN

ENTER

RUN
JOG

PROGRAM

START

STOP

RESET

SPEED
VOLTS

AMPS

Hz

Kw

TORQUE

Password

RUNNING

REMOTE

JOG

AUTO

FORWARD

REVERSE

PROGRAM