Programming Reference

4-61

The adjusted values may be in any order. The frequency will not be affected at normal
acceleration or deceleration but will be avoided at continuous output frequency.

.

The avoided frequency range is:

(Avoidance freq. midpoint ‘n’ - freq. band ‘n’/2) < range < (avoidance freq. midpoint ‘n’ + freq. band ‘n’/2)

where n = 1, 2, or 3.

H.010, H.012, H.014 Avoidance Frequency Midpoint 1, 2, and 3

This parameter
specifies the midpoint
of each avoidance
frequency band
selected in H.011,
H.013, and H.015.

Parameter Range:

0.0 to 200.0 Hz

Default Setting:

0.0

Parameter Type:

Tunable

Refer also to parameters:

H.009 Avoidance Frequency Enable
H.011, H.013, H.015 Avoidance Frequency Band 1,

2, and 3

H.011, H.013, and H.015 Avoidance Frequency Band 1, 2, and 3

This parameter
specifies the
avoidance frequency
band that will be
applied to each
avoidance frequency
midpoint selected in
H.010, H012, and
H.014.

Parameter Range:

0.2 to 10 Hz

Default Setting:

2.0

Parameter Type:

Tunable

Refer also to parameters:

H.009 Avoidance Frequency Enable
H.010, H.012, H.014 Avoidance Frequency Midpoint

1, 2, and 3