Chapter 5

Using the RS–232 Ports

5–20

This function can only be executed once per command.

Refer to Appendix D for a description of the configuration blocks. You
cannot use this command when the CVIM module is in the setup mode.
When the CVIM module is receiving configuration blocks from a Host, the
CVIM module will leave the active run mode and ignore any input triggers
(setup menu option is also disabled). After receiving one or more new
configuration blocks, the CVIM module will validate the entire configuration
since many of the operating parameters are interrelated.

Example:

>W,CB1 [CR] 00__F1__

etc.

This example writes the
data 00, F1, etc. into
configuration block #1.
“_” = space character.

Example:

>WC,CB1,CB30–35,CB21[CR](data)

This example
writes the data
into the specified
blocks.

After executing the command, the CVIM module will return: [CR][LF]. No
data is returned. If you do not have the proper command structure, the CVIM
module will return: ?[CR][LF].

Note: We recommend that you check the discrete bit ‘‘configuration fault’’
after loading a configuration. Refer to Appendix B. You can check this bit
by using the read inspection results command for toolset #1, (>RR,S [CR]).

Write Configuration (W)
Write Configuration (WC)
(cont’d)