beautypg.com

Rockwell Automation 5370 CVIM Communications Manual User Manual

Page 121

background image

Chapter 5

Using the RS-232 Ports

5–51

Table 5.B
DF1 Command Summary (Cont’d)

Command

Command Structure

Field Descriptions

07 00 n x y z

n =

times repeated

x =

04 (Toolset 1)
05 (Toolset 5)

y =

16(Gages)
17 (Window)
18 (Reference Line)
19 (Reference
Window
1A (Light Probe)

z =

Window, Gage,
Reference Line, or
Reference Window
No.

Read Results Block

07 00 n 10 Data

Toolset 1 Results
n = times repeated
Data = Block Number(s) 1, 2,
3 or 4

07 00 n 15 Data

Toolset 2 Results
n = times repeated
Data = Block Number(s) 1, 2,
3 or 4

07 00 n 04

Toolset 1 discrete bit results
n = times repeated

07 00 n 05

Toolset 2 discrete bit results
n = times repeated

07 00 n 08

Read Status

Save to EEPROM from
RAM

08 00

Save to RAM Card from
RAM

08 01 Data

Data = 01 (area 1)

02 (area 2)

D D D

15(area 15)
16(area 16)

Set ConfigurabIe Results

OD Flags

Flags indicate specific tools

Set ConfigurabIe Statistics

16 00 n Flags

Flags indicate specific tools
n = times repeated

Read ConfigurabIe Statistics

17 00 n

n = times repeated

Trigger Inspection

09

Trigger

Write Configuration Block

0B 07 Flags Data

Flags indicate blocks