Appendix C
Numerical Results Data

C–12

The fourth results block may be formatted and read through any of the
communications ports. This block has user defined contents. This block may
contain up to 64 words of data; see Table C.4.

Table C.4
Numerical Results Data – Results Block #4

Word #

Bit #

Function

Notes

0

0 – 15

Block Transfer Signature

1

0 – 15

Status

The contents of this word will be 0 if all of the requested
data fits in the 64 word results block. Otherwise, the
contents will be non–0.

2 – 61

0 – 15

User Defined Inspection Results Data

62 – 63

0 – 15

Task Triggers (32 Bits)

Each type of result requires a specific number of words. Use the following as
a guideline when setting up a programmable block transfer.

Number of Words

Format

Module Status

1 Word

X/Y Reference Line

2 Words

16 Bit Integer

Window

2 Words

(Object & Pixel)

32 Bit Integer

(Luminance)

16 Point 16

(Template)

32 Bit Integer

(Gradient)

32 Bit Integer

Brightness Probe

2 Words

16 Point 16

Reference Window

14 Words

16 Bit Integer

and

16 Point 16

Gage

2 Words

(Linear Measure)

16 Point 16

(Edge, Pixel, Object)

32 Bit Integer

X, Y Position

16 Point 16

If you request more results than will fit into 62 words, the CVIM will
truncate the data and set an error bit in word 1.

Note: Refer to discrete output word description (word 3) on Page 4 – 18 for
information on how to send a programmable block format request to the
CVIM.