Rockwell Automation 5370 CVIM Communications Manual User Manual
Page 88
Chapter 5
Using the RS–232 Ports
5–18
Example of Read Statistics Command:
> RS5[CR]
This example reads the statistics block five
times.
The data returned from the statistics block consists of:
•
Block signature
Number of samples, maximum, minimum, average, and standard
deviation for each tool configured in the block.
The block signature is 2 bytes long. The number of samples is a 2 byte
integer. The maximum and minimum values are each 4 bytes. The format of
the data depends upon the operation (e.g. pixel count is an integer and linear
gaging is a 16.16 fixed point value). Refer to page C–24 for data formats.
Standard deviations are also 4 bytes each but are always 16.16 fixed point
values. Averages are 24.8 fixed point values. Therefore, each tool statistic
consists of 18 bytes with the exception of reference windows which contain
18 bytes for each feature or a total of 54 bytes. The statistics block is
transmitted as two hexadecimal characters for each byte. The total number of
bytes including the block signature should not exceed 128 bytes. The
statistics block is read once for every number of specified samples. This
means that if you read the statistics block five times with a sample number of
50, 250 triggers will have to be processed before the five reads are
completed. The following shows the format of the returned data:
Statistics Block Returned Data Format
Set/Read Configurable