Accessing discrete bit information (cont’d) – Rockwell Automation 5370 CVIM Communications Manual User Manual
Page 47

Chapter 4
Using the Remote I/O Link
(Node Adapter)
4–10
Table 4.B
CVIM Module Remote I/O Outputs (PLC to CVIM Module)if CVIM Module is Rack 02
BIT
07
–––
17
06
–––
16
05
–––
15
04
–––
14
03
–––
13
02
–––
12
01
–––
11
00
–––
10
W
O
R
D
(Reserved)***
(Reserved)***
(Not Used)
(Not Used)
(Not Used)
(Not Used)
(Not Used)
(Not Used)
(Not Used)
1 = Config
Transfer
1 = I/O
Request
1 = Light pen
Request
1 = Trigger
Toolset 2
1 = Trigger
Toolset 1
1 = Unlock
Setup
1 = Lock
Setup
20
(Not Used)
1 = Display
Stat 2 Page
1 = Display
Stat 1 Page
1 = Display
Results Page
1 = Display
I/O Page
1 = Display
All Tools
1 = Display
Failed Tools
1 = Display
Image Only
21
(Not Used)
(Not Used)
(Not Used)
Halt on Reject
1 = Freeze
Next Image
1 = Freeze All
Rejects
1 = Freeze
First Reject
Go on reject
21
1 = Enable
JMB Forces
1 = Disable
JMB Forces
1 = Enable
JMB Outputs
1 = Disable
JMB Outputs
(Not Used)
(Not Used)
1 = Post TS2
to Remote I/O
1 = Post TS1
to Remote I/O
22
1 = Credit
Card Config.
(8’s bit)****
1 = Credit
Card Config.
(4’s bit)****
1 = Credit
Card Config.
(2’s bit)****
1 = Credit
Card Config.
(1’s bit)****
1 = RAM to
Credit Card
1 = Credit
Card to RAM
1 = RAM to
EEPROM
1 = EEPROM
to RAM
22
(Not Used)
(Not Used)
1 =Toolset 2
Request
Results Block
1 = Toolset 1
Request
Results Block
1 = Last Block
(write Only)
Block Transfer
Type *
Block Transfer
Type *
Block Transfer
Type *
23
1 = Block
Trnsfer Block
No. (128’s bit)
1 = Block
Trnsfer Block
No. (64’s bit)
1 = Block
Trnsfer Block
No. (32’s bit)
1 = Block
Trnsfer Block
No. (16’s bit)
1 = Block
Trnsfer Block
No. (8’s bit)
1 = Block
Trnsfer Block
No. (4’s bit)
1 = Block
Trnsfer Block
No. (2’s bit)
1 = Block
Trnsfer Block
No. (1’s bit)
23
1 = Force JMB
Output 8 ON**
1 = Force JMB
Output 7 ON**
1 = Force JMB
Output 6 ON**
1 = Force JMB
Output 5 ON**
1 = Force JMB
Output 4 ON**
1 = Force JMB
Output 3 ON**
1=Force JMB
Output 2 ON**
1=Force JMB
Output 1 ON**
24
(Not Used)
(Not Used)
1 = Force
JMB Output
14 ON**
1 = Force
JMB Output
13 ON**
1 = Force
JMB Output
12 ON**
1 = Force
JMB Output
11 ON**
1 = Force
JMB Output
10 ON**
1 = Force
JMB Output 9
ON**
24
1 = Force
JMB Output 8
OFF**
1 = Force
JMB Output 7
OFF**
1 = Force
JMB Output 6
OFF**
1 = Force
JMB Output 5
OFF**
1 = Force
JMB Output 4
OFF**
1 = Force
JMB Output 3
OFF**
1 = Force
JMB Output 2
OFF**
1 = Force
JMB Output 1
OFF**
25
(Not Used)
(Not Used)
1 = Force
JMB Output
14 OFF**
1 = Force
JMB Output
13 OFF**
1 = Force
JMB Output
12 OFF**
1 = Force
JMB Output
11 OFF**
1 = Force
JMB Output
10 OFF**
1 = Force
JMB Output 9
OFF**
25
1 = Reset
Counters
1 = Reset
Stats
1 = Page
Down
1 = Page Up
1 = Resume
Control
(Not Used)
1 = Display
Toolset 2
1 = Display
Toolset 1
26
(Not Used)
(Not Used)
(Not Used)
(Not Used)
(Not Used)
(Not Used)
(Not Used)
(Not Used)
26
(Not Used)
(Not Used)
(Not Used)
(Not Used)
(Not Used)
(Not Used)
(Not Used)
(Not Used)
27
(Not Used)
(Not Used)
(Not Used)
(Not Used)
(Not Used)
(Not Used)
(Not Used)
(Not Used)
27
*
Set these three bits to specify the type of block as follows: 001 = Results, 010 = Configuration, 100 = Template, 101 = Statistics,
111 = Programmable Results Block Write
**
If both ON & OFF bits are set, the output is forced OFF.
***
Do not write to these bits.
**** The first configuration on the card is 0000.
Accessing Discrete
Bit Information (cont’d)