Chapter 3

Using Local I/O

3–4

Output Line 5: The Results function is assigned to line 5. The Fault
Range result from camera A probe is assigned to line 5.

Output Line 6: The Results function is assigned to line 6. The Warning
and Fault Range results for gages 1 and 2 of toolset #2 are assigned to
line 6.

Output Line 7: The Strobe function for toolset #1 is assigned to line 7.

Output Line 8: The Trigger NAK function for toolset #1 is assigned to
line 8.

Output Line 9: The Master Fault function for toolset #1 is assigned to
line 9.

Output Line 10: The Data Valid function for toolset #1 is assigned to line
10.

Output Line 11: The Module Busy function is assigned to line 11. (Note
that this function does not relate to a toolset).

Output Lines 12–14: These lines are not used.

Note: Output lines 1–6 are assigned the Results function. These lines will
carry “pass/fail” results from the analysis tools to your production
equipment. Lines 7–11 are assigned other functions. Lines 12–14 are not
used.

Here is a brief explanation of the signal functions that you can assign to the
output lines:

Module Busy: This signal goes high when the CVIM system enters the
configuration mode and during a configuration download operation.
Module Busy goes low when the system enters the run mode (whether or
not triggers are present).

You can assign the Module Busy function to only one output line.

Note: When configurations are being downloaded to the CVIM module, the
module busy signal at the JMB board is not active.

Note: All of the remaining signal functions (except Strobe, Module Busy,
and Trigger NAKs) can be configured to produce a pulse whose duration
depends on the number of milliseconds that you assign to the Duration/1 or
Duration/2 parameter. (The ‘‘1’’ and ‘‘2’’ designate toolset #1 and toolset
#2).

1/Results: This signal occurs when the results of a tool inspection exceed
the warning and/or fault limits. (The tool must be assigned to an output
line that has already been assigned the Results function.)

Using the Output Line