beautypg.com

Rockwell Automation 5370 CVIM Communications Manual User Manual

Page 22

background image

Chapter 3

Using Local I/O

3–3

Here is an example of how an Output Line Planning Sheet could be filled
out:

Example CVIM Module Output Line Planning Sheet
Output Line Functions and Tool Assignments

Line

Output Line

Tool

Set

Gage

Window

Reference

Tool

Light Probe

No.

Function

Set
No.

No.

Rng.

No.

Rng.

No.

Rng.

No.

Rng.

Line

Win.

Cam.

Rng.

1

Results

1

1

W

2

W

1

W

2

W

3

W

4

W

2

Results

1

1

F

2

F

1

F

2

F

3

F

4

F

3

Results

1

1

1

4

Results

1

A

W

5

Results

1

A

F

6

Results

2

1

W

1

F

2

W

2

F

7

Strobe

1

8

Trig. NAK

1

9

Master Fault

1

10

Data Valid

1

11

Module Busy

NA

12

Not Used

13

Not Used

14

Not Used

The entries for the output lines have the following meanings:

Output Line 1: The Results function is assigned to line 1. The Warning
Range results (W) for gages 1–4 and windows 1 and 2 of toolset #1 are
assigned to output line 1.

Output Line 2: The Results function is assigned to line 2. The Fault
Range results (F) for gages 1–4 and windows 1 and 2 of toolset #1 are
assigned to output line 2.

Output Line 3: The Results function is assigned to line 3. The “pass/fail”
results for reference line 1 of toolset #1 and reference window 1 are
assigned to line 3.

Output Line 4: The Results function is assigned to line 4. The Warning
Range result from the camera A light probe is assigned to line 4. Camera
A is assigned to toolset #1.